Acceuil

> Catalogues

Encapsulated 50-60 Hz

Myrra provides an extensive range of high quality encapsulated transformers for PCB.

The category can be divised into two lines :

  • 44000 Series : Cost-effective range
  • 45000 Series : Low-profile range

Both ranges are isolated and sizes are from EI30 to EI66 (44000 Series) or UI30 to UI48 (45000 Series).

Produced in our warehouses in China & Poland, stocks are most likely available in a short delay.

Overview

  • 0.6 to 60 VA
  • Sizes :
    • EI30 to EI66 (44000 Series)
    • UI30 to UI48 (45000 Series)
  • UL and VDE (EI sizes – 230 V input ) certificated as per IEC60950 and EN61558-2-6

Encapsulated LF

Encapsulated 50-60 Hz

Encapsulated 50-60 Hz

filter Filtre
Image Part No. Rated Power (VA) Primary Voltage (V) Secondary Voltage (V) Low Profile / Standard Secondary Current (mA) Ambient (°C) Drawing Designation
44013 0.6 230 6 Standard 100 70 EI30-5 - 230 / 6V - 0.6 VA
44014 0.6 230 9 Standard 66 70 EI30-5 - 230 / 9V - 0.6 VA
44015 0.6 230 12 Standard 50 70 EI30-5 - 230 / 12V - 0.6 VA
44016 0.6 230 15 Standard 40 70 EI30-5 - 230 / 15V - 0.6 VA
44017 0.6 230 18 Standard 33 70 EI30-5 - 230 / 18V - 0.6 VA
44018 0.6 230 24 Standard 25 70 EI30-5 - 230 / 24V - 0.6 VA
44019 0.6 230 2 x 6 Standard 2 x 50 70 EI30-5 - 230 / 2 x 6V - 0.6 VA
44020 0.6 230 2 x 9 Standard 2 x 33 70 EI30-5 - 230 / 2 x 9V - 0.6 VA
44021 0.6 230 2 x 12 Standard 2 x 25 70 EI30-5 - 230 / 2 x 12V - 0.6 VA
44022 0.6 230 2 x 15 Standard 2 x 20 70 EI30-5 - 230 / 2 x 15V - 0.6 VA
44023 0.6 230 2 x 18 Standard 2 x 17 70 EI30-5 - 230 / 2 x 18V - 0.6 VA
44024 0.6 230 2 x 24 Standard 2 x 12 70 EI30-5 - 230 / 2 x 24V - 0.6 VA
44025 0.6 117 6 Standard 100 70 EI30-5 - 117 / 6V - 0.6 VA
44026 0.6 117 9 Standard 66 70 EI30-5 - 117 / 9V - 0.6 VA
44027 0.6 117 12 Standard 50 70 EI30-5 - 117 / 12V - 0.6 VA
44028 0.6 117 15 Standard 40 70 EI30-5 - 117 / 15V - 0.6 VA
44029 0.6 117 18 Standard 33 70 EI30-5 - 117 / 18V - 0.6 VA
44030 0.6 117 24 Standard 25 70 EI30-5 - 117 / 24V - 0.6 VA
44031 0.6 117 2 x 6 Standard 2 x 50 70 EI30-5 - 117 / 2 x 6V - 0.6 VA
44032 0.6 117 2 x 9 Standard 2 x 33 70 EI30-5 - 117 / 2 x 9V - 0.6 VA
44033 0.6 117 2 x 12 Standard 2 x 25 70 EI30-5 - 117 / 2 x 12V - 0.6 VA
44034 0.6 117 2 x 15 Standard 2 x 20 70 EI30-5 - 117 / 2 x 15V - 0.6 VA
44035 0.6 117 2 x 18 Standard 2 x 17 70 EI30-5 - 117 / 2 x 18V - 0.6 VA
44036 0.6 117 2 x 24 Standard 2 x 12 70 EI30-5 - 117 / 2 x 24V - 0.6 VA
44049 1 230 6 Standard 167 70 EI30-10.5 - 230 / 6V - 1 VA